BEGIN:VEVENT
DTSTART;TZID=UTC:20201230T090000
DTEND;TZID=UTC:20201230T110000
DTSTAMP:20260404T025632
CREATED:20201230T010205Z
LAST-MODIFIED:20201230T010205Z
UID:8204-1609318800-1609326000@ricselectric.net
SUMMARY:Bob Hering - Ben
DESCRIPTION:Time and Materials \nMake sure tools are on cardboard and not on any finished surfaces \nClean up behind yourself thoroughly and leave no dust or debris\, use vacuum cleaner. \nSlide dishwasher over and connect to wiring \nFlush range receptacle and putty pad box for fire wall installation. \nReverse island junction box so that it is behind the cooler. Remove MC cable feeding first outlet and bring down to new junction box location. They can’t install shelf how it is now. \nStrap other MC Cable up tight to second receptacle box\, it can stay how it is run just needs strapping. \n 
URL:https://ricselectric.net/event/bob-hering-ben-2/
LOCATION:Bob Hering\, 180 Nautica Mile Dr.\, Clermont\, Fl.\, FL\, United States
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=UTC:20201222T070000
DTEND;TZID=UTC:20201222T153000
DTSTAMP:20260404T025632
CREATED:20201221T233320Z
LAST-MODIFIED:20201221T233320Z
UID:8008-1608620400-1608651000@ricselectric.net
SUMMARY:Bob Hering - Ben\, Billy\, Josh C.
DESCRIPTION:Time and Materials \nMaterials in shop\, make sure you have everything you need before going over there based on list below\, if we miss anything get with Josh C. and he can run it over there. \nBilly has other jobs then can fall in and help if he has time \nPriority in order \nRefrigerator \nMicrowave (goof ring\, sin receptacle plate needed) \nDishwasher 6′ cord and metal romex connector \nDisposal 3′ cord and metal romex connector \nInsta Hot 3′ cord and metal romex connector \nMake receptacle under sink in to a quad \nIsland wiring\, receptacle for cooler \nIsland receptacles with USB ports x 2 \nUCL and ACL tape lighting\, make sure we have 16/2 and a power supply everywhere we need it. \nCircuit down stairs \n7:00am
URL:https://ricselectric.net/event/bob-hering-ben-billy-josh-c/
LOCATION:Bob Hering\, 180 Nautica Mile Dr.\, Clermont\, Fl.\, FL\, United States
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=UTC:20201214T120000
DTEND;TZID=UTC:20201214T153000
DTSTAMP:20260404T025632
CREATED:20201214T002502Z
LAST-MODIFIED:20201214T113307Z
UID:7792-1607947200-1607959800@ricselectric.net
SUMMARY:Bob Hering - Ben\, Nick
DESCRIPTION:Time and Materials \nKitchen remodel\, goof rings needed and long screws. 3 – USB type receptacles\, kitchen island wiring for 2 receptacles\, MC cable\, fittings\, F clips\, straps\, connecting dishwasher and disposal. \nin wall coffee maker (may not be able to do) block on one wall\, fire wall on the other. \nLighting circuit downstairs quit working mysteriously. \n321.229.4488 \n(after noon)
URL:https://ricselectric.net/event/bob-hering-ben/
LOCATION:Bob Hering\, 180 Nautica Mile Dr.\, Clermont\, Fl.\, FL\, United States
END:VEVENT