Temporaries – Matt, Tanner
November 17, 2020 @ 7:00 am - 10:00 am
Contract
All underground, make sure they do not have bypass handles in the meters. Make sure they are all good to go to pass inspection, no open KOs, breaker blanks, all receps GFI protected or removed and blanked off, WR GFIs, Heavy or Extra Duty in use covers.
Weber Residence – Green Valley – 15035 Green Valley Blvd., Clermont, set UG T Pole (two ground rods 6′ or more apart)
HBH (Bella Collina) – Lot 75, 112 – Lake Estate Side – set UG T Pole (one ground rod each)
Not till we pass inspection;
Need sub temp on 112 run down the property line in conduit, not buried, schedule 80 3/4″ 150′- 200′ with 4 – #10s (black, red, white, green) on a 2 pole 20 amp in a 2 gang box post mounted with 2 – GFIs and a in use cover
7:00am